不断超越,追求完美

效率成就品牌,诚信铸就未来

只有更好的服务,才有更多的用户

  • 麦融高科热管一体化机房专用空调,专为数据中心与通讯基站节能设计

  • 热管一体化机房*空调是专为数据中心及通信*节能而设计的节能产品,有效地解决高热密度环境空调能耗高的难题。

    机组能够根据机房室内外温差,自动选择空调制冷模式或热管模式运行。

    机组结构上分为分体型和整体型两种,应用于数据中心、通信*、*和金融系统机房。

    The integrated unit combined heat pipe and air conditioning is designed for data centers and telecommunications base stations to reduce the energy consumption of air conditioners in high heat density spaces. It switches running modes automatically according to outdoor and indoor air temperatures and humidities. This unit can be integrated in one or split into two parts for data centers, telecommunications base stations, and government and financial systems’ machine rooms.   工作原理 Work Principle 空调制冷模式:当室外温度较高或室内负荷较大,自然冷源无法满足*降温需求时,机组自动切换至空调制冷模式运行。

    此时,热管系统的节能模块自动关闭,空调制冷系统开启。

    热管模式:当室内、外温度满足使用需求时,机组关闭空调制冷循环,自动切换进入热管换热模式运行,此时机组的综合能效比达8.0以上。

    Air conditioning mode: when outdoor air temperature is high or indoor cooling load is large, natural cold source cannot satisfy cooling demand. Under these conditions, the unit runs under the air conditioning mode. Heat pipe mode: when outdoor air temperature and humidity meet the cooling demand, this unit switches to heat pipe mode automatically. Under this condition, the mean energy efficiency ratio (EER) is higher than 8.0.   产品特性 Product Feature 1、大风量、小焓差、高显热比设计; 2、采用全封闭柔性涡旋式压缩机,具有噪声低、效率高,运行稳定等特点; 3、采用*热力膨胀阀、电磁阀,使系统始终在*状态点运行; 4、采用加大的蒸发器,Φ9.52mm铜管串亲水膜铝箔片,进一步提高机组EER值; 5、采用工业级控制器,稳定性更强,操作方便简洁;支持标准通信协议实现远程管理; 1 It has larger air volumetric flow rate, lower enthalpy difference, and higher sensible heat ratio. 2 It runs stably and high efficiently with low noise for the application of closed flexible scroll compressor. 3 It runs at the optimal point with the use of famous thermostatic expansion valve. 4 It has high EER for the use of larger evaporator that is made of Φ 9.52 mm copper pipes with hydrophilic film aluminum foil. 5 It is easy to co*ol for the use of industrial co*oller and can be co*olled remotely.   技术参数表 Technical Parameter 机 组 型 号 Type SCLS-5500 SCLS-7500 SCLS-12500 机械制冷量(w) Cooling Capacity (W) 5500 7500 12500 自然显冷量(w) Sensible Heat (W) 3060 4035 6050 额定功率(空调/热管)(w) Power (Air Conditioning / Heat Pipe) (W) 2000/240 2750/450 4850/540 电源 Power Supply 220V-50HZ/380V-50HZ 内循环风量(m/h) Inside circulating air flow rate (m/h) 2600 3000 5000 外循环风量(m/h) Outside circulating air flow rate (m/h) 2000 3100 5500 宽×深×高(mm) W×D×H (mm) 550×550×1680 650×650×1850 800×800×1900 重量(kg) Weight (kg) 98 149 198 使用环境温度(℃) Temperature Range (℃) -40—55 标签: 热管一体 热管空调 机房专用   热管一体机 热管空调 机房专用空调   长沙市机房空调   长沙市机房空调厂家
    [热管一体机 热管空调 机房空调] 长沙市机房空调厂家
    麦融高科热管一体化机房专用空调,专为数据中心与通讯基站节能设计
  • 企业信息
  • 状态:匆匆过客
  • 核实:        
  • IP属地:广东省